Revolutionary Innovation in Gas Purification Technology

The GENESIS has been designed to be the most cost effective stainless steel inert atmosphere glovebox system on the market.

The GENESIS was born from VAC’s ongoing research and development and our pursuit to simplify the user experience by advancements in inert atmosphere technologies.

Each system is supplied with integrated independent inert gas purifiers. The Genesis Purifier Cartridges are supplied pre-activated and ready for immediate use. Our revolutionary patented design is able to achieve and maintain glovebox oxygen and moisture purity levels of < 1 ppm.

This design eliminates the need for high maintenance external gas purification columns, circulation blowers, regeneration valves, regeneration control systems or requirements for regeneration gas.

VAC’s Cartridge Technology has changed the way the world thinks about inert atmosphere purification methods.

No Regeneration Required.
Genesis cartridge and base

Genesis Cartridge Purification Technology

Every Genesis Glovebox System comes with oxygen and moisture purification as standard.

Oxygen Purification

Includes an atmosphere circulation assembly, power supply, and oxygen removal cartridge. These low cost cartridges are designed to be replaced by fully activated replacements purchased exclusively from Vacuum Atmospheres Company.

Moisture Purification

Includes an atmosphere circulation assembly, power supply, and moisture removal cartridge. These low cost cartridges are designed to be replaced by fully activated replacements purchased from exclusively Vacuum Atmospheres Company.

Technical Data

Performance: < 1 ppm oxygen & moisture

Antechamber pump down time: 6 minute cycle (typical)

Leak Certification: Helium leak check to 1 X 10-6 std cc/sec.

Safety Certification: Conforms and certified to UL Std 61010-1 and CSA Std C22.2 NO 1010.1, certified for CE conformity

Oxygen Analyzer Assy, : LCD display, calibration system and electrolytic fuel cell. Monitors and displays the glovebox levels from 0.1 ppm to 25% oxygen.

Moisture Analyzer Assy: LCD display, aluminum oxide probe with NIST traceable calibration. Monitors and displays the glovebox levels to 0.5-ppm moisture (-80°C dew point)

Pressure Control:  Glovebox pressure is monitored and controlled by the Dwyer Photohelic® gauge, a proven pressure control component for decades. The pressure Control rang is +/- 5 inches of water column (+/- 12.4 mbar).

Purifiers: Each has 3 speed settings; Off, Low, and High.

Antechamber: 9.38” x  9.38” x 12” (internal dimensions)

Genesis 2 Port

45" W x 30" D x 36" H

(1143mm x 762mm x 914mm)

Genesis 4 Port Dual Length

112" W X 30" D X 36" H

(2844mm x 762mm x 914mm)

  • Single Length, Single Sided: 45″ Width, 30″ Depth, 36″ Height, (1143mm x 762mm x 914mm), 2 Glove Ports, 700 Lb Weight
  • Extra Length, Single Sided: 68″ Width, 30″ Depth, 36″ Height, (1727mm x 762mm x 914mm), 3 Glove Ports, 850 Lb Weight
  • Double Length, Single Sided: 90″ Width, 30″ Depth, 36″ Height, (2286mm x 762mm x 914mm), 4 Glove Ports, 950 Lb Weight
  • Single Length, Dual Sided: 45″ Width, 45″ Depth, 36″ Height, (1143mm x 1143mm x 914mm), 4 Glove Ports, 950 Lb Weight
  • Custom Configurations available upon request 
  • Glovebox: Single Sided and Single Length (2 Port). 45″ wide x 30″ deep x 36″ height (1143 x 762 x 914 mm), stainless steel construction with removable end panels. Full view 1⁄4” thick scratch-resistant polycarbonate front window, with aluminum glove ports. One dual AC electrical junction box (for customer use) and one dual DC electrical junction box (for purifier power) inside of glovebox.
  • Stand: Welded steel construction supporting the glovebox, instrumentation and controls. Stand has height levelers and casters. System can be ordered without stand.
  • Antechamber: 9.38” x 9.38” x 12” (internal dimensions) stainless steel construction, mounted on right panel. Manual ball valves for evacuation and refill.
  • Oxygen Purification Kit: Includes circulation assembly and oxygen removal cartridge. These low cost cartridges are designed to be replaced by fully activated replacements purchased exclusively  from Vacuum Atmospheres Company.
    P/N VAC 109038
  • Moisture Purification Kit: Includes circulation assembly and moisture removal cartridge. These low cost cartridges are designed to be replaced by fully activated replacements purchased exclusively from Vacuum Atmospheres Company.
    P/N VAC 109037
  • Analyzer Assy, Oxygen: LCD display, calibration system and electrolytic fuel cell. Monitors and displays the glovebox levels from 0.1 ppm to 25% oxygen. Our electrochemical-based sensor is not affected by hydrocarbons and is specific to oxygen. P/N VAC 109297
  • Analyzer Assy, Moisture: LCD display, aluminum oxide probe with NIST traceable calibration. Monitors and displays the glovebox levels to 0.5-ppm moisture (-80°C dew point). P/N VAC 401301
  • Glovebox Purge: Manual 1 1⁄2” ball valve. Standard feature.
  • LED Light: Energy efficient glovebox luminaire, 4500K color temperature for optimum visibility in glovebox. Standard feature.
  • Shelves: One set of three adjustable shelves, 8 inches deep x 24 inches wide (203 x 610 mm). Standard feature.
  • Glove Port Cover: Protects atmosphere during glove replacement. One cover included as standard.
  • Gloves: One pair included with each system.
  • Power: 115 or 230 VAC, 50/60 Hz Operation. See the Request For Quote below for part numbers
  • Vacuum Pump: Edwards RV5, 4.1 cfm direct drive pump included with each system, see options for other choices.
  • Pressure Control: Glovebox pressure is monitored and controlled by the Dwyer Photohelic® gauge.

Key Benefits

  • No user regeneration required.

  • No down time for regeneration
  • No regeneration gas needed.
  • No purifier service required.
  • 9.38″ x 9.38″ x 12″ antechamber (internal dimensions) , with comparable cross sectional area as a traditional 15″ diameter cylindrical antechamber with approximately one third the cycle time (6 minute cycle time).
  • Smaller footprint minimizes space taken up in the lab, allows for easy dock to lab transfer, minimizes elevator concerns and reduces shipping costs. 
  • Lower cost of ownership. 
  • Simplified training for new users. 
  • Genesis uses 50% less power than traditional glovebox systems. 

Options

Options

Freezer

The VAC CS-40+ is a refrigeration system designed to provide 20.9L of -35°C refrigerated storage space inside an inert atmosphere glovebox.

Solvent Purification

Our patented recirculation loop purifies solvents to a nearly moisture free condition, with many purification options available.

Ovens

Two versions available: a water jacketed oven for operation to 600° C and an insulation blanketed oven for operation to 200° C.

Glovebox Cooling

The VAC Dri-Kool systems are air-cooled or water-cooled mechanical refrigeration systems designed for cooling inert gas glovebox atmospheres.

Microscope

The VAC MD-50 Digital Microscope is built for up close work from a distance.

Solvent Trap

VAC’s Solvent Trap is designed to remove organic solvent vapors from the glove box Atmosphere.

Common Accessories

  • Interface Assy, NW40-KF: Welded feedthru penetration into a glovebox.
  • Interface Assy, NPT: Welded threaded feedthru penetrations into a glovebox. Also vacuum feedthru with 1/4″ valves on interior and exterior of glovebox.
  • Interface Assy, 20 amp: 5-way binding post feedthrus for electrical signals. P/N VAC 100626
  • 9 Pin, D-sub, P/N VAC 401161
  • 15 Pin, D-sub, P/N VAC 401162
  • 25 Pin, D-sub, P/N VAC 401163
  • RJ-45, P/N VAC 401164
  • USB, P/N VAC 400980
  • Interface Assy, BNC, P/N VAC 100627
  • Workstation Ionizer, No Fan: Excellent static control for working with an analytical balance or powders. Free standing.
    P/N VAC 101373, 110 VAC, 60 Hz
    P/N VAC 101467, 220 VAC, 50 Hz
  • Workstation Ionizer, with Fan: For coverage of greater work area. Free standing.
    P/N VAC 400259, 110 VAC, 60 Hz
    P/N VAC 400260, 220 VAC, 50 Hz
Please see quote request form below for full list of Options and Accessories.